Veritas amplifiers can sense when a ControlCenter CC-1 (level control only) or CC-2 (level + A/B source selector) is connected.
By default, the amplifier will revert to Input B as the selected source when a CC-1 is connected. You can change this setting in the Settings menu.
Relevant Product(s)
- Veritas 2160BH
- Veritas 2160BL
- Veritas 1100BH
- Veritas 250BL
Issue
No sound after connecting one or more CC-1s.
Procedure
1. Go to Settings by pressing and holding the front panel encoder wheel for 3 seconds.
2. Scroll to Src Sel and chose Front. Now you can use the front panel source switch to select Input A or Input B.
Alternately, if you only have 1 audio source, you can move this to Input B, and this will remain the only selectable source.