This article describes how to update the ControlSpace CC-64 firmware using the manual updater utility software called CC64Programmer.exe or CC64UpdateUtility.exe.
Relevant Product(s)
- ControlSpace CC-64
Procedure
Very occasionally, the Firmware Updater from the Hardware Manager in ControlSpace Designer will have difficulty updating a ControlSpace CC-64. This will result in an "update failed" message in ControlSpace Designer.
When this occurs update with the following steps:
- Navigate to the ControlSpace bin folder; C:\Program Files (x86)\Bose\ControlSpace [version]\bin folder.
- Each version of CSD contains a new firmware version. So be sure to use the correct CSD /bin folder
- Run the CC64UpdateUtility.exe program
- Prior to ControlSpace Designer Version 4.3 this was call CC64Programmer.exe.
- Select the appropriate CC-64 from the list and select Program
- The Utility will auto-populate the firmware contained in the /bin folder.
If the update fails again, bypass the network switch and plug the CC-64 directly into the PC's LAN port using a crossover network cable.