Views:

This article provides information about a known Issue and an available workaround.

 

Symptom

When the complete Sound System is powered on the CC-64 does not show the selected Parameter Set.

 

Relevant Product(s)

  • ControlSpace CC-64
  • ControlSpace ESP-88
  • ControlSpace ESP-00
  • ControlSpace ESP-00-II
  • ControlSpace ESP-1240
  • ControlSpace ESP-4120
  • ControlSpace ESP-880
  • ControlSpace ESP-1600
  • ControlSpace ESP-880A
  • ControlSpace ESP-880AD
  • ControlSpace ESP-120A
  • ControlSpace ESP-1240AD
  • ControlSpace EX-440C
  • ControlSpace EX-1280
  • ControlSpace EX-1280C

 

Resolution

Move the control knob or press it. Once it has a selection, it will continue to display the currently selected Parameter Set until next time the system is power cycled.
(Interaction forces the CC-64 to try to sync with the DSP again)

A Workaround can be a sequential Power On Management with a Timer for the CC-64. Include a 60 seconds delay between the powering on of the DSP powering the CC-64. When the CC-64 starts 60 seconds or more after the DSP it is able to sync and can now show direct the selected Parameter Set.

 

Why did this happen?

The CC-64's boot time is much faster than the boot time of a processor, therefore the CC-64 is ready and cannot sync with the DSP because the DSP is still booting.

Add a comment