Views:

In this article, we explain how to use parameter sets to lock and unlock a ControlSpace CC-64.

A possible use case is in a conference room that is partitioned and alternates between being used as two independent rooms and as a single, large room. When the two rooms are combined into a single space, one of the CC-64s can be locked so that the other CC-64 is the sole controller.

 

Relevant Product(s)

  • ControlSpace CC-64
  • ControlSpace Designer

 

Procedure

In this example, the CC-64 that performs the lock and unlock operations is labelled CC-64 #1, and the CC-64 that is locked is CC-64 #2.

 

1. Open the programming panels of CC-64 #1 and CC-64 #2 in the Project View of ControlSpace Designer. Click the LOCK button of CC-64 #2 to lock it, and then assign it to a parameter set by dragging the CC-64 block onto an available parameter set:

 

2. Unlock CC-64 #2, and then assign it to a different parameter set:

 

3. Assign the parameter set which contains the lock state to a control of CC-64 #1 by clicking and dragging the parameter set onto a control:

 

4. Assign the parameter set which contains the unlock state to the same control of CC-64 #1.

 

5. Confirm that CC-64 #2 can be locked and unlocked by CC-64 #1.

Comments (0)
Add a comment